Qauv: DF6100- EH DopplerHandheld Ultrasonic Flow Meteryog tsim los ntsuas volumetric ntws ntawm nyob rau hauv kaw conduit, cov yeeb nkab kab yuav tsum muaj tag nrho cov kua, thiab yuav tsum muaj ib tug npaum li cas ntawm cov huab cua npuas los yog tshem tawm cov khib nyiab nyob rau hauv cov kua.
Doppler ultrasonic flow meter tuaj yeem tso saib tus nqi ntws thiab ntws tag nrho, thiab lwm yam, thiab tau teeb tsa nrog 4-20mA, OCT outputs.
Nta
Nws yog tsim rau cov yeeb nkab loj li ntawm 40 mus rau 4000mm
Rau cov kua dej qias neeg, yuav tsum muaj cov npuas npuas lossis cov khoom uas raug tshem tawm
Zoo heev uas tsis tshua muaj peev xwm ntsuas ntsuas, qis rau 0.05m / s
Ntau yam kev ntsuas ntws, siab txaus tuaj yeem ncav cuag 12m / s
High-temperature transducer yog haum rau cov kua dej ntawm -35 ℃ ~ 200 ℃
Tsis tas yuav kaw cov yeeb nkab ntws thaum txhim kho cov transducers
Cov neeg siv-phooj ywg configuration
4-20mA, OCT tso zis
Qhov tseeb: 2.0% Calibrated ncua
Rechargeable roj teeb tuaj yeem ua haujlwm txog li 14 teev
Cov lus qhia tshwj xeeb
Transmitter:
Kev ntsuas txoj cai | Doppler ultrasonic |
Kev daws teeb meem | 0.25mm / s |
Rov ua dua | 0.5% ntawm kev nyeem ntawv |
Qhov tseeb | 0.5% - 2.0% FS |
Teb sijhawm | 2-60s rau kev xaiv |
Flow Velocity Range | 0.05-12m / s |
Ua kua hom txhawb | Cov kua dej uas muaj 100ppm ntawm cov reflectors thiab tsawg kawg 20% ntawm cov reflectors loj dua 100 micron. |
Fais fab mov | AC: 85-265V Mus txog 14 teev nrog cov roj teeb uas muaj tag nrho |
Enclosure hom | Handheld |
Qib kev tiv thaiv | IP65 raws li EN60529 |
Ua haujlwm kub | -20 ℃ to + 60 ℃ |
Cov khoom siv tsev | ABS |
Kev ntsuas raws | 1 |
Zaub | 2 kab × 8 cim LCD, 8-tus lej lossis 8-tus lej tag nrho (resettable) |
Chav tsev | Tus neeg siv Configured (Lus Askiv thiab Metric) |
Tus nqi | Rate thiab Velocity Display |
Totalized | gallons, ft³, barrels, lbs, litres, m³, kg |
Kev sib txuas lus | 4-20mAOCTtso zis |
keypad | 6pcs nyees khawm |
Loj | Transmitter: 237X125X42mm Case: 410X320X80mm |
Qhov hnyav | 0,6kg ib |
Transducer:
Hom Transducers | Clamp-on |
Qib kev tiv thaiv | IP65.IP67 lossis IP68 raws li EN60529 |
Suited Ua Kua Dej Kub | Std.Temp.: -35 ℃ ~ 85 ℃ rau lub sijhawm luv txog li 120 ℃ |
Kub kub: -35 ℃ ~ 200 ℃ rau lub sijhawm luv txog li 250 ℃ | |
Txoj kab uas hla | 40-4000 hli |
Transducer Loj | 60 (h) * 34 (w) * 32 (d) mm |
Khoom siv ntawm transducer | Aluminium rau standard temp.sensor, thiab peek rau high temp.sensor |
Cable Ntev | ib: 5m |
Configuration Code
DF6100-EH | Handheld Doppler Ultrasonic Flowmeter | |||||||||||||||||
Fais fab mov | ||||||||||||||||||
A | 85-265VAC | |||||||||||||||||
Kev xaiv tso zis 1 | ||||||||||||||||||
N | N/A | |||||||||||||||||
1 | 4-20mA | |||||||||||||||||
2 | OCT | |||||||||||||||||
Kev xaiv tso zis 2 | ||||||||||||||||||
Ib yam li saum toj no | ||||||||||||||||||
Hom Sersor | ||||||||||||||||||
D | Txheem Clamp-on transducer (DN40-4000) | |||||||||||||||||
Transducer Kub | ||||||||||||||||||
S | -35~85℃(rau lub sijhawm luv mus txog 120℃) | |||||||||||||||||
H | -35~200℃ | |||||||||||||||||
Txoj kab uas hla | ||||||||||||||||||
DNX | DN40-40mm, DN4000-4000mm | |||||||||||||||||
Cable ntev | ||||||||||||||||||
5m | 5m (standard 5m) | |||||||||||||||||
Xm | Common cable Max 300m(Standard 5m) | |||||||||||||||||
XmH | Kub kub.cable Max 300 m | |||||||||||||||||
DF6100-EH | — | A | — | 1 | — | N/LDH | — | D | — | S | — | DN100 | — | 5m | (piv txwv configuration) |